重慶升降機是建筑中經(jīng)常使用的載人載貨升降機械,,由于其獨特的箱體結(jié)構(gòu)使其乘坐起來既舒適又安全,升降平臺在使用中需配備哪些保護裝置呢,?
1,、地面圍欄門保護:應(yīng)有機械聯(lián)鎖裝置和電氣安全開關(guān),當工作臺離開地面位置時,,門應(yīng)不能打開,;當門打開時,電氣安全開關(guān)應(yīng)使寧波升降平臺停止或不能起動,。
Ground fence door protection: should the mechanical and electrical safety interlock switch, when the table off the ground position, the door should not be opened; when the door is opened,electrical safety switch should make Ningbo stop or not start lifting platform.
2,、檢修安全門保護:應(yīng)設(shè)置電氣安全開關(guān),當門打開時,,寧波升降平臺應(yīng)停止或不能起動,。
Access security door protection: electrical safety switch should be set when the door is opened, Ningbo lifting platform should stop or not start.
3、樓層圍欄門保護:應(yīng)設(shè)置可以人工打開的門鎖裝置和電氣安全開關(guān),,門鎖應(yīng)不能從樓層一側(cè)打開,,只能從工作臺一側(cè)打開,門鎖裝置應(yīng)由重力保持鎖緊,,鎖緊時鎖止元件的嵌入深度不應(yīng)少于7mm,,當門開啟和門鎖未鎖緊時,電氣安全開關(guān)應(yīng)使施工升降機停止或不能起動,。
Floor protection fence gate: setting can be manually opened the door and electrical safety switches, door should not be opened from one side of the floor, the table can only be opened from the side of the door locking device by gravity to keep locking embedding depth of not less than the locking element 7mm, when the door opened and unlocked the door, electrical safety switch should be stopped or not start construction lifts.
4,、緊急操作:應(yīng)當在底層設(shè)有在斷電或發(fā)生故障時使升降機下降的緊急操作裝置,并有明顯標記;該裝置應(yīng)依靠持續(xù)力進行控制,如采用控制手柄時,,手柄的操作方向應(yīng)當與控制的功能運動方向一致,當松開控制手柄時應(yīng)當自動回到"停"或中間位置,。
Emergency Operation: There should be a power failure or malfunction when making an emergency operation device lifts the decline, and clearly marked on the ground floor; the device should continue to rely on force to control, such as the use of the control handle, the operator shall handle the direction and control function of movement in the same direction, when you release the control handle should automatically return to the "stop" or intermediate position.
5、防人員剪切保護:服務(wù)樓層大于或等于3層的升降平臺,,當工作臺與樓層井口的水平間距小于0.5m時,,工作臺底部周邊應(yīng)設(shè)置防碰撞裝置,當下降碰到障礙時,應(yīng)使升降機停止,。當工作臺的圍欄高度小于1.8m時,應(yīng)在井口樓板的下緣用撓性件(如鏈條)懸掛無銳利邊緣的垂直防碰擋板,其下垂高度不應(yīng)小于0.3m,。
Anti-personnel Cut Protection: service is greater than or equal to 3-layer floor lifting platform, when the horizontal distance between the table and the floor wellhead less than 0.5m, the bottom of the table should be set around the anti-collision device, when the decline encountered obstacles, should make lift stops. When the table fence height is less than 1.8m, no sharp edges should be suspended vertically in the lower edge of the anti-collision baffle wellhead floor with flexible member (such as chain), its sagging height of not less than 0.3m.